Grid interconnection
Utility coordination, high-voltage service, and substation design to bring firm capacity onto your site — and a realistic schedule for when it arrives.
Apptek Energy designs, builds, and operates the electrical infrastructure behind data centers — from grid interconnection to the rack — with the redundancy AI and cloud workloads demand.
A single AI rack can now draw more power than an entire aisle did a decade ago. The grid, not the floor space, is the new constraint.
Apptek Energy exists to solve that constraint. We take a data center from a power question — how many megawatts, how fast, how reliably — to a commissioned, monitored, and maintained electrical plant. One partner from the utility connection to the last PDU, accountable for the thing your uptime actually depends on.
We work across the full electrical stack, so redundancy, capacity, and efficiency are designed together — not bolted on after the fact.
Utility coordination, high-voltage service, and substation design to bring firm capacity onto your site — and a realistic schedule for when it arrives.
Prime and standby generation sized to your load, with transfer schemes that keep compute online through utility events measured in cycles, not minutes.
Battery and rotary UPS architectures built to N+1 and 2N, so a single component failure is never a single point of failure for the load.
Medium- and low-voltage distribution engineered for high rack density — from switchgear and busway to the PDU feeding the cabinet.
Solar, storage, and firm supply blended into a mix that moves you toward sustainability targets without trading away reliability.
Real-time telemetry across every feed and breaker, tied to an operations team watching the load and responding around the clock.
A power plant for compute is a sequence, not a shopping list. Each stage de-risks the next, and we own the outcome the whole way through.
Load profile, growth curve, site constraints, and available utility capacity.
Single-line diagrams, redundancy tier, efficiency targets, and interconnection plan.
Utility coordination, substation, and energization of firm service to the site.
Integrated testing to design load before the first server is ever installed.
24/7 monitoring, maintenance, and capacity planning as your footprint scales.
From the substation at the property line to the panels on the roof, the physical plant is where reliability is won or lost.
Send the megawatts you need and when you need them online. We'll come back with a feasible interconnection path, a redundancy tier, and a schedule — not a brochure.